CABLExpress beefs up Skinny-Trunk data cabling infrastructure line - Connector Specifier

CABLExpress beefs up Skinny-Trunk data cabling infrastructure line


Mar 18, 2010

CABLExpress, a manufacturer of data center and cabling infrastructure, has announced its expanded Skinny-Trunk Solution, a high-density trunking system designed to increase flexibility and improve performance in a structured data centers. The product line now includes the Skinny-Trunk fiber trunk assemblies, the Skinny-Trunk Z-Mount, Skinny-Trunk Harnesses, H-Series Enclosures and the Skinny-Trunk Fiber Jumpers.

RELATED NEWS:  CABLExpress enhances Skinny-Trunk fiber optic MTP connector

The Skinny-Trunk Z-Mount is a universal mount, metal bracket manufactured by CABLExpress that attaches to the outside of any standard rack or cabinet. It is billed as the only bracket on the market with molded, angled MTP couplers. The Skinny-Trunk fiber-optic trunking cables snap into the back of the bracket and a Skinny-Trunk Harness plugs into the front, therefore eliminating the need to utilize an additional enclosure inside the rack. This may reduce the use of vertical rack space, saving room for future expansion.

For large switches, the company says the combination of the Skinny-Trunk Z-Mount and Skinny-Trunk Harness also eliminates the need to attach fiber jumpers to a patch panel, which may help to decrease cabling by up to 70 percent. Skinny-Trunk Fiber Jumpers are still available for smaller switches.

The Skinny-Trunk Harness features customized, pre-engineered, staggered lengths that meet the specifications of high-density Brocade, Cisco and other switches. The MTP breakout legs on the Skinny-Trunk Harness vary in length and plug into the angled Z-Mount bracket, which reduces bend radius and insertion loss.

The MTP breakout legs on a Skinny-Trunk and a Skinny-Trunk Harness are only 3 mm in diameter, which may reduce cable congestion compared to breakout legs that are typically 5-6 mm.

"The CABLExpress Skinny-Trunk Solution allows companies to save space, reduce insertion loss and future-proof their data centers," says Peter E. Belyea, vice president of data center cabling for the company. "By using pre-engineered, customized lengths and reducing the overall amount of cabling required, it really cleans up the data center and helps reduce the amount of cooling required."

In January 2010, CABLExpress also announced an enhancement to the 12 fiber optic MTP connector on its Skinny-Trunk 12-fiber trunk assembly. The MTP connector combines an improved ferrule design that features more precise fiber alignment with an enhanced polishing technique during the manufacturing process. As a result, Skinny-Trunks have been successfully tested to reduce insertion loss by 40 percent, which translates to more allowed connections. With the new thermoplastic ferrule design, typical insertion loss on Skinny-Trunk MTP assemblies is reduced to 0.15 dB and the number of connection points may be increased up to 24.

With the improved ferrule design and enhanced proprietary polishing process, customers are able to maintain proper interconnect points to stay within TIA-942 standards and migrate to higher speeds without replacing cable assemblies.

All Skinny-Trunk products carry a lifetime guarantee, and the H-series Enclosures have a five-year warranty.

For more information, visit www.cablexpress.com, www.twitter.com/cablexpress, or call 315-476-3000.


Editor's Picks

Incapable connectors shut down Large Hadron Collider

Amphenol: Bulking up via buyout

NASA unveils deep space MPCV exploration craft; Lockheed Martin responds

As UAV market surges, connectors adapt

NHTSA pressures Ford into mass F-150 truck recall on airbag wiring danger

Esterline acquiring Souriau for $715 million

Report: Single trader holds half of world's copper


Top Blog Posts

Inside Foxconn's deadly iPad factory after the blast

Fireproof electronic connectors: design challenges

Connector industry giants saw banner 2010 sales growth

Tearing down Apple's Thunderbolt cable

Massive solar tower will rank among world's tallest buildings


Most Popular Articles
Top Articles for 2011

Boeing exec admits 787 outsourcing strategy backfired

Foxconn staggering after full year net loss of $200M+

The Motley Fool' pits Amphenol vs. Molex

ITT issues military-aerospace connector sourcebook

SATA-IO unveils portable consumer storage specification

Raytheon locks in LaBarge for cruise missiles' wiring harnesses post-Libya bombing

Union group denies Verizon fiber lines vandalized

Northrop Grumman seeks to replace copper-based aircraft wire, cabling

Driving wiring harness design data toward manufacturing


Latest Community Discussions

Video: Fire breaks out at Foxconn's Shandong plant
Bystander video shows the scene of a fire breaking out on September 27 at Foxconn's Yantai Shandong plant where Sony consumer electronics products are reportedly assembled.

Testing the Boeing 787 Dreamliner's in-flight entertainment systems
Boeing video shows what was involved in testing (i.e. "trying to break") the in-flight entertainment, connectivity, and power systems on board the new 787 Dreamliner.

Belden FiberExpress Brilliance LC Connector Installation
Video details installation of a 900-micron OM3/OM4 prepped fiber into an LC connector.

Visit the Community >


Receive Free E-mail Newsletters from Interconnection World


You may select more than one newsletter  
Interconnection World
Connector Specifier
Wire & Harness Specifier

 
Name  
 
Email  
 
Country  
 
 
 

 
Sponsor Information

Interconnection World Content Categories:

Wire & Harness
 Data & Telecom
Standards Distributors
Design & Test Applications
Business Wire News
Video